STUDY OF THE EFFECT OF A NEW COMBINED INHIBITOR AND A PERMANENT MAGNETIC FIELD ON CORROSION AND SALT DEPOSITION

Авторы

  • K.A.Mammedov

Ключевые слова:

oilfield equipment, salt deposition, inhibitor, aggression, composite, corrosion

Аннотация

This academic article encompasses the investigation results concerning, the composite acquired from
the mixture of hydrated technical phosphatide, cubic thickness of polypropylene glycol, and sodium
hexametaphosphate. According to the outcomes of laboratory researches, it was determined that the developed new
composite provides not only prevention of equipment from corrosion, but also protection of those from salt
deposition. Furthermore, as a result of the joint effect of a stable magnetic field of 280 kA/m, high protective
efficiency was determined. Thus, the optimum consumption was found to be 150 mg/l. In this case, the protection
effectiveness against corrosion and salt deposition accounted for 93% and 85% accordingly.
Commercial tests of the combined action of the reagent and the permanent magnetic field were carried out on
the cooling system of compressors “Bibiheybatneft” OGED (Oil and Gas Extraction Department). In the field with
the combined use of a magnetic field and inhibitors the protective effect is 90%, and the protective effect of salt
deposition is 73%

Загрузки

Опубликован

2020-03-29

Как цитировать

K.A.Mammedov. (2020). STUDY OF THE EFFECT OF A NEW COMBINED INHIBITOR AND A PERMANENT MAGNETIC FIELD ON CORROSION AND SALT DEPOSITION. Известия НАН РК. Серия химии и технологии, (2), 145–152. извлечено от http://189185.vm7pq.group/chemistry-technology/article/view/926